| Type | Rated operat ing current(A) |
Rated voltage(V) |
Current Setting range | |
| S3UA-50 | 12.5 | 690 | 0.1-0.1,0.16-0.25,0.25-0.4,0.32-0.63,0.63-0.1,0.8-1.25,1-1.6 1.25-2,1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5 |
|
| S3UA-52 | 25 | 690 | 0.1-0.1,0.16-0.25,0.25-0.4,0.32-0.63,1.63-1,0.8-1.25,1-1.6 1.25-2,1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5 10-16,12.5-20,16-25 |
|
| S3UA-54 | 32 | 690 | 4-6,6.3-10,10-16,12.5-20,16-25,20-32 | |
| S3UA-58 | 80 | 690 | 16-25,20-32,25-40,32-50,40-57,50-63,57-70,63-80 | |
| S3UA-59 | 63 | 690 | 0.1-0.16,0.16-0.25,0.25-0.4,0.4-0.63,1.63-1,0.8-1.25,1-1.6,1.25-2 1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5,10-16,12.5-20 16-25,20-32,25-40,32-45,40-57,50-63 |
|
| S3UA-62 | 180 | 690 | 55-80,63,90,80-110,90-120,110-135,120-150,135-160,150-180 | |
| S3UA-66 | 400 | 1000 | 80-125,125-200,200-320,250-400 | |
| S3UA-68 | 630 | 1000 | 320,-500,400-630 | |
| Family | OEM Part no. | amp min | amp max | Contactors suitable for |
| 3UA50 | 3UA50-40-0A | 0.1 | 0.16 | 3TF30, 3TF31, 3TF40, 3TF41, 3TB40, 3TB41 |
| 3UA50-40-0C | 0.16 | 0.25 | ||
| 3UA50-40-0E | 0.25 | 0.4 | ||
| 3UA50-40-0G | 0.4 | 0.63 | ||
| 3UA50-40-0J | 0.63 | 1 | ||
| 3UA50-40-0K | 0.8 | 1.25 | ||
| 3UA50-40-1A | 1 | 1.6 | ||
| 3UA50-40-1B | 1.25 | 2 | ||
| 3UA50-40-1C | 1.6 | 2.5 | ||
| 3UA50-40-1D | 2 | 3.2 | ||
| 3UA50-40-1E | 2.5 | 4 | ||
| 3UA50-40-1F | 3.2 | 5 | ||
| 3UA50-40-1G | 4 | 6.3 | ||
| 3UA50-40-1H | 5 | 8 | ||
| 3UA50-40-1J | 6.3 | 10 | ||
| 3UA50-40-1K | 8 | 12.5 | ||
| 3UA50-40-2S | 10 | 14.5 | ||
| 3UA52 | 3UA52-40-0A | 0.1 | 0.16 | 3TF30, 3TF31, 3TF40, 3TF41, 3TB40, 3TB41 |
| 3UA52-40-0C | 0.16 | 0.25 | ||
| 3UA52-40-0E | 0.25 | 0.4 | ||
| 3UA52-40-0G | 0.4 | 0.63 | ||
| 3UA52-40-0J | 0.63 | 1 | ||
| 3UA52-40-0K | 0.8 | 1.25 | ||
| 3UA52-40-1A | 1 | 1.6 | ||
| 3UA52-40-1B | 1.25 | 2 | ||
| 3UA52-40-1C | 1.6 | 2.5 | ||
| 3UA52-40-1D | 2 | 3.2 | ||
| 3UA52-40-1E | 2.5 | 4 | ||
| 3UA52-40-1F | 3.2 | 5 | ||
| 3UA52-40-1G | 4 | 6.3 | ||
| 3UA52-40-1H | 5 | 8 | ||
| 3UA52-40-1J | 6.3 | 10 | ||
| 3UA52-40-1K | 8 | 12.5 | ||
| 3UA52-40-2A | 10 | 16 | ||
| 3UA52-40-2B | 12.5 | 20 | ||
| 3UA52-40-2C | 16 | 25 | ||
| 3UA54 | 3UA54-40-1G | 4 | 6.3 | 3TF44, 3TB44 |
| 3UA54-40-1J | 6.3 | 10 | ||
| 3UA54-40-2A | 10 | 16 | ||
| 3UA54-40-2B | 12.5 | 20 | ||
| 3UA54-40-2C | 16 | 25 | ||
| 3UA54-40-2D | 20 | 32 | ||
| 3UA54-40-2Q | 25 | 36 | ||
| 3UA55 | 3UA55-40-0A | 0.1 | 0.16 | 3TF34, 3TF35, 3TF44, 3TF45 |
| 3UA55-40-0C | 0.16 | 0.25 | ||
| 3UA55-40-0E | 0.25 | 0.4 | ||
| 3UA55-40-0G | 0.4 | 0.63 | ||
| 3UA55-40-0J | 0.63 | 1 | ||
| 3UA55-40-0K | 0.8 | 1.25 | ||
| 3UA55-40-1A | 1 | 1.6 | ||
| 3UA55-40-1B | 1.25 | 2 | ||
| 3UA55-40-1C | 1.6 | 2.5 | ||
| 3UA55-40-1D | 2 | 3.2 | ||
| 3UA55-40-1E | 2.5 | 4 | ||
| 3UA55-40-1F | 3.2 | 5 | ||
| 3UA55-40-1G | 4 | 6.3 | ||
| 3UA55-40-1H | 5 | 8 | ||
| 3UA55-40-1J | 6.3 | 10 | ||
| 3UA55-40-1K | 8 | 12.5 | ||
| 3UA55-40-2A | 10 | 16 | ||
| 3UA55-40-2B | 12.5 | 20 | ||
| 3UA55-40-2C | 16 | 25 | ||
| 3UA55-40-2D | 20 | 32 | ||
| 3UA55-40-2Q | 25 | 36 | ||
| 3UA55-40-2R | 32 | 40 | ||
| 3UA55-40-8M | 36 | 45 | ||
| 3UA58 | 3UA58-40-1G | 4 | 6.3 | 3TF46, 3TF47, 3TF48, 3TF49 |
| 3UA58-40-2B | 12.5 | 20 | ||
| 3UA58-40-2C | 16 | 25 | ||
| 3UA58-40-2D | 20 | 32 | ||
| 3UA58-40-2E | 25 | 40 | ||
| 3UA58-40-2F | 32 | 50 | ||
| 3UA58-40-2P | 50 | 63 | ||
| 3UA58-40-2T | 40 | 57 | ||
| 3UA58-40-2U | 53 | 80 | ||
| 3UA58-40-2V | 57 | 70 | ||
| 3UA58-40-8A | 11 | 17 | ||
| 3UA58-40-8W | 70 | 88 | ||
| 3UA59 | 3UA59-40-0A | 0.1 | 0.16 | 3TF30- 3TF35, 3TF40-3TF46 |
| 3UA59-40-0C | 0.16 | 0.25 | ||
| 3UA59-40-0E | 0.25 | 0.4 | ||
| 3UA59-40-0G | 0.4 | 0.63 | ||
| 3UA59-40-0J | 0.63 | 1 | ||
| 3UA59-40-0K | 0.8 | 1.25 | ||
| 3UA59-40-1A | 1 | 1.6 | ||
| 3UA59-40-1B | 1.25 | 2 | ||
| 3UA59-40-1C | 1.6 | 2.5 | ||
| 3UA59-40-1D | 2 | 3.2 | ||
| 3UA59-40-1E | 2.5 | 4 | ||
| 3UA59-40-1F | 3.2 | 5 | ||
| 3UA59-40-1G | 4 | 6.3 | ||
| 3UA59-40-1H | 5 | 8 | ||
| 3UA59-40-1J | 6.3 | 10 | ||
| 3UA59-40-1K | 8 | 12.5 | ||
| 3UA59-40-2A | 10 | 16 | ||
| 3UA59-40-2B | 12.5 | 20 | ||
| 3UA59-40-2C | 16 | 25 | ||
| 3UA59-40-2D | 20 | 32 | ||
| 3UA59-40-2E | 25 | 40 | ||
| 3UA59-40-2M | 32 | 45 | ||
| 3UA59-40-2P | 50 | 63 | ||
| 3UA59-40-2T | 40 | 57 | ||
| 3UA60 | 3UA60-40-2H | 55 | 80 | 3TF49, 3TF50, 3TB50 |
| 3UA60-40-2W | 63 | 90 | ||
| 3UA60-40-2X | 80 | 110 | ||
| 3UA60-40-3H | 90 | 120 | ||
| 3UA60-40-3J | 110 | 135 | ||
| 3UA60-40-3J | 110 | 135 | ||
| 3UA61 | 3UA61-40-2H | 55 | 80 | 3TF51 |
| 3UA61-40-2W | 63 | 90 | ||
| 3UA61-40-2X | 80 | 110 | ||
| 3UA61-40-3H | 90 | 120 | ||
| 3UA61-40-3J | 110 | 135 | ||
| 3UA61-40-3K | 120 | 150 | ||
| 3UA62 | 3UA62-40-2H | 55 | 80 | 3TF52, 3TF53, 3TB52 |
| 3UA62-40-2W | 63 | 90 | ||
| 3UA62-40-2X | 80 | 110 | ||
| 3UA62-40-3H | 90 | 120 | ||
| 3UA62-40-3J | 110 | 135 | ||
| 3UA62-40-3K | 120 | 150 | ||
| 3UA62-40-3L | 135 | 160 | ||
| 3UA62-40-3M | 150 | 180 | ||
| 3UA66 | 3UA66-40-2K | 80 | 125 | 3TF54, 3TF55, 3TF56, 3TF57 |
| 3UA66-40-3B | 125 | 200 | ||
| 3UA66-40-3C | 160 | 250 | ||
| 3UA66-40-3D | 200 | 320 | ||
| 3UA66-40-3E | 250 | 400 | ||
| 3UA68 | 3UA68-40-3F | 320 | 500 | 3TF57, 3TF68 |
| 3UA68-40-3G | 400 | 630 | 3TF57, 3TF68 |
Product detail pictures:

Related Product Guide:
Does Tesla Make The Best Value EVSE For Non-Tesla Owners? | Lrd12 Overload Relay
Who’s really being silenced on Twitter? | Lrd12 Overload Relay
The corporation keeps to the operation concept "scientific management, superior quality and performance primacy, consumer supreme for OEM Supply Single Phase Solid State Contactor - 3UA overload relay – Simply Buy, The product will supply to all over the world, such as: Iran , New Zealand , Uruguay , We win many reliable customers by rich experience, advanced equipments, skilled teams, strict quality control and best service. We can guarantee all our products. Customers' benefit and satisfaction are always our biggest goal. Please contact us. Give us a chance, give you a surprise.
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
-
factory Outlets for Ac Magnet Contactor - Moto...
-
100% Original Factory 48vdc Magnetic Contactor ...
-
2017 Good Quality Street Light Reflector - ZL3...
-
China Factory for General Purpose Power Relay A...
-
Discountable price d12 Telemecanique Ac Contact...
-
Europe style for Lc1-n 3/4phase Reversing Conta...