New Fashion Design for Siemens Overload Thermal Relay - NB1-63 Four Pole din rail circuit breaker – Simply Buy Detail:
DC MCB1(Mini circuit breaker)supplementary protectors are designed to provide over current protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.It’s din rail mounted type and Current form 1A to 63A and voltage 110VDC ,125VDC to 250VDC 440V DC .
Features:
• B C trip curves models available for general
use and DC applications
• D trip curve models available for high starting
current applications such as motor starting
• Current ratings up to 63A
• Maximum 480VAC (multi-pole), 277VAC (single-pole)
• 5000 A Interrupt Rating
• DIN rail mount chassis
• Captive terminal screws won’t fall out
• Mechanical life: 20000 times.
• Electric life: 4000 times
• Captive terminal screws won’t fall out
Tripping curves
B curve
When the short-circuit currents are weak (generators, long cables).
Power circuit:
ratings: 1 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 3 and 5 In.
C curve
Cables feeding conventional loads.
Power circuit:
ratings: 0.5 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 5 and 10 In.
D curve
Loads with high inrush currents (motors, transformers).
Power circuit:
ratings: 0.5 to 63 A set at 40 °C
tripping curve: the magnetic trip units operate between 10 and 14 In.
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
| B Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-B1-1P | MCB1-B1-2P | MCB1-B1-3P | MCB1-B1-4P |
| 2 | MCB1-B2-1P | MCB1-B2-2P | MCB1-B2-3P | MCB1-B2-4P | |
| 3 | MCB1-B3-1P | MCB1-B3-2P | MCB1-B3-3P | MCB1-B3-4P | |
| 4 | MCB1-B4-1P | MCB1-B4-2P | MCB1-B4-3P | MCB1-B4-4P | |
| 6 | MCB1-B6-1P | MCB1-B6-2P | MCB1-B6-3P | MCB1-B6-4P | |
| 10 | MCB1-B10-1P | MCB1-B10-2P | MCB1-B10-3P | MCB1-B10-4P | |
| 16 | MCB1-B16-1P | MCB1-B16-2P | MCB1-B16-3P | MCB1-B16-4P | |
| 20 | MCB1-B20-1P | MCB1-B20-2P | MCB1-B20-3P | MCB1-B20-4P | |
| 25 | MCB1-B25-1P | MCB1-B25-2P | MCB1-B25-3P | MCB1-B25-4P | |
| 32 | MCB1-B32-1P | MCB1-B32-2P | MCB1-B32-3P | MCB1-B32-4P | |
| 40 | MCB1-B40-1P | MCB1-B40-2P | MCB1-B40-3P | MCB1-B40-4P | |
| 50 | MCB1-B50-1P | MCB1-B50-2P | MCB1-B50-3P | MCB1-B50-4P | |
| 63 | MCB1-B63-1P | MCB1-B63-2P | MCB1-B63-3P | MCB1-B63-4P | |
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
| C Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-C1-1P | MCB1-C1-2P | MCB1-C1-3P | MCB1-C1-4P |
| 2 | MCB1-C2-1P | MCB1-C2-2P | MCB1-C2-3P | MCB1-C2-4P | |
| 3 | MCB1-C3-1P | MCB1-C3-2P | MCB1-C3-3P | MCB1-C3-4P | |
| 4 | MCB1-C4-1P | MCB1-C4-2P | MCB1-C4-3P | MCB1-C4-4P | |
| 6 | MCB1-C6-1P | MCB1-C6-2P | MCB1-C6-3P | MCB1-C6-4P | |
| 10 | MCB1-C10-1P | MCB1-C10-2P | MCB1-C10-3P | MCB1-C10-4P | |
| 16 | MCB1-C16-1P | MCB1-C16-2P | MCB1-C16-3P | MCB1-C16-4P | |
| 20 | MCB1-C20-1P | MCB1-C20-2P | MCB1-C20-3P | MCB1-C20-4P | |
| 25 | MCB1-C25-1P | MCB1-C25-2P | MCB1-C25-3P | MCB1-C25-4P | |
| 32 | MCB1-C32-1P | MCB1-C32-2P | MCB1-C32-3P | MCB1-C32-4P | |
| 40 | MCB1-C40-1P | MCB1-C40-2P | MCB1-C40-3P | MCB1-C40-4P | |
| 50 | MCB1-C50-1P | MCB1-C50-2P | MCB1-C50-3P | MCB1-C50-4P | |
| 63 | MCB1-C63-1P | MCB1-C63-2P | MCB1-C63-3P | MCB1-C63-4P | |
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
| D Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-D1-1P | MCB1-D1-2P | MCB1-D1-3P | MCB1-D1-4P |
| 2 | MCB1-D2-1P | MCB1-D2-2P | MCB1-D2-3P | MCB1-D2-4P | |
| 3 | MCB1-D3-1P | MCB1-D3-2P | MCB1-D3-3P | MCB1-D3-4P | |
| 4 | MCB1-D4-1P | MCB1-D4-2P | MCB1-D4-3P | MCB1-D4-4P | |
| 6 | MCB1-D6-1P | MCB1-D6-2P | MCB1-D6-3P | MCB1-D6-4P | |
| 10 | MCB1-D10-1P | MCB1-D10-2P | MCB1-D10-3P | MCB1-D10-4P | |
| 16 | MCB1-D16-1P | MCB1-D16-2P | MCB1-D16-3P | MCB1-D16-4P | |
| 20 | MCB1-D20-1P | MCB1-D20-2P | MCB1-D20-3P | MCB1-D20-4P | |
| 25 | MCB1-D25-1P | MCB1-D25-2P | MCB1-D25-3P | MCB1-D25-4P | |
| 32 | MCB1-D32-1P | MCB1-D32-2P | MCB1-D32-3P | MCB1-D32-4P | |
| 40 | MCB1-D40-1P | MCB1-D40-2P | MCB1-D40-3P | MCB1-D40-4P | |
| 50 | MCB1-D50-1P | MCB1-D50-2P | MCB1-D50-3P | MCB1-D50-4P | |
| 63 | MCB1-D63-1P | MCB1-D63-2P | MCB1-D63-3P | MCB1-D63-4P |
Product detail pictures:





Related Product Guide:
Motor Nameplate Current vs. NEC Full Load Current Values | National Electrical Code | Circuit Breaker Parts
Pioneer debuts three new wireless CarPlay systems | Lrd12 Overload Relay
No matter new shopper or old customer, We believe in very long expression and dependable relationship for New Fashion Design for Siemens Overload Thermal Relay - NB1-63 Four Pole din rail circuit breaker – Simply Buy, The product will supply to all over the world, such as: Cairo , Azerbaijan , Turkey , We confirm to public, cooperation, win-win situation as our principle, adhere to the philosophy of make a living by quality, keep developing by honesty , sincerely hope to build up a good relationship with more and more customers and friends, to achieve a win-win situation and common prosperity.
Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
-
Chinese wholesale Lighting Fixtures For Led Tub...
-
OEM Manufacturer Polyester Copper Wire For Seal...
-
Big discounting Electric Contactor 24v - Motor...
-
Rapid Delivery for 3tf-45 Telemecanique Ac Cont...
-
Good Wholesale Vendors Rc Electric Starter - 3...
-
Low MOQ for Excellent Electromagnetic Contactor...

