Short Lead Time for Lc1d475 Magnetic Contactor Schneider - NB1-63 Three Pole din rail circuit breaker – Simply Buy Detail:
DC MCB1(Mini circuit breaker)supplementary protectors are designed to provide over current protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.It’s din rail mounted type and Current form 1A to 63A and voltage 110VDC ,125VDC to 250VDC 440V DC .
Features:
• B C trip curves models available for general
use and DC applications
• D trip curve models available for high starting
current applications such as motor starting
• Current ratings up to 63A
• Maximum 480VAC (multi-pole), 277VAC (single-pole)
• 5000 A Interrupt Rating
• DIN rail mount chassis
• Captive terminal screws won’t fall out
• Mechanical life: 20000 times.
• Electric life: 4000 times
• Captive terminal screws won’t fall out
Tripping curves
B curve
When the short-circuit currents are weak (generators, long cables).
Power circuit:
ratings: 1 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 3 and 5 In.
C curve
Cables feeding conventional loads.
Power circuit:
ratings: 0.5 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 5 and 10 In.
D curve
Loads with high inrush currents (motors, transformers).
Power circuit:
ratings: 0.5 to 63 A set at 40 °C
tripping curve: the magnetic trip units operate between 10 and 14 In.
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole | 
| B Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC  | 
1 | MCB1-B1-1P | MCB1-B1-2P | MCB1-B1-3P | MCB1-B1-4P | 
| 2 | MCB1-B2-1P | MCB1-B2-2P | MCB1-B2-3P | MCB1-B2-4P | |
| 3 | MCB1-B3-1P | MCB1-B3-2P | MCB1-B3-3P | MCB1-B3-4P | |
| 4 | MCB1-B4-1P | MCB1-B4-2P | MCB1-B4-3P | MCB1-B4-4P | |
| 6 | MCB1-B6-1P | MCB1-B6-2P | MCB1-B6-3P | MCB1-B6-4P | |
| 10 | MCB1-B10-1P | MCB1-B10-2P | MCB1-B10-3P | MCB1-B10-4P | |
| 16 | MCB1-B16-1P | MCB1-B16-2P | MCB1-B16-3P | MCB1-B16-4P | |
| 20 | MCB1-B20-1P | MCB1-B20-2P | MCB1-B20-3P | MCB1-B20-4P | |
| 25 | MCB1-B25-1P | MCB1-B25-2P | MCB1-B25-3P | MCB1-B25-4P | |
| 32 | MCB1-B32-1P | MCB1-B32-2P | MCB1-B32-3P | MCB1-B32-4P | |
| 40 | MCB1-B40-1P | MCB1-B40-2P | MCB1-B40-3P | MCB1-B40-4P | |
| 50 | MCB1-B50-1P | MCB1-B50-2P | MCB1-B50-3P | MCB1-B50-4P | |
| 63 | MCB1-B63-1P | MCB1-B63-2P | MCB1-B63-3P | MCB1-B63-4P | |
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole | 
| C Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC  | 
1 | MCB1-C1-1P | MCB1-C1-2P | MCB1-C1-3P | MCB1-C1-4P | 
| 2 | MCB1-C2-1P | MCB1-C2-2P | MCB1-C2-3P | MCB1-C2-4P | |
| 3 | MCB1-C3-1P | MCB1-C3-2P | MCB1-C3-3P | MCB1-C3-4P | |
| 4 | MCB1-C4-1P | MCB1-C4-2P | MCB1-C4-3P | MCB1-C4-4P | |
| 6 | MCB1-C6-1P | MCB1-C6-2P | MCB1-C6-3P | MCB1-C6-4P | |
| 10 | MCB1-C10-1P | MCB1-C10-2P | MCB1-C10-3P | MCB1-C10-4P | |
| 16 | MCB1-C16-1P | MCB1-C16-2P | MCB1-C16-3P | MCB1-C16-4P | |
| 20 | MCB1-C20-1P | MCB1-C20-2P | MCB1-C20-3P | MCB1-C20-4P | |
| 25 | MCB1-C25-1P | MCB1-C25-2P | MCB1-C25-3P | MCB1-C25-4P | |
| 32 | MCB1-C32-1P | MCB1-C32-2P | MCB1-C32-3P | MCB1-C32-4P | |
| 40 | MCB1-C40-1P | MCB1-C40-2P | MCB1-C40-3P | MCB1-C40-4P | |
| 50 | MCB1-C50-1P | MCB1-C50-2P | MCB1-C50-3P | MCB1-C50-4P | |
| 63 | MCB1-C63-1P | MCB1-C63-2P | MCB1-C63-3P | MCB1-C63-4P | |
| Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole | 
| D Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC  | 
1 | MCB1-D1-1P | MCB1-D1-2P | MCB1-D1-3P | MCB1-D1-4P | 
| 2 | MCB1-D2-1P | MCB1-D2-2P | MCB1-D2-3P | MCB1-D2-4P | |
| 3 | MCB1-D3-1P | MCB1-D3-2P | MCB1-D3-3P | MCB1-D3-4P | |
| 4 | MCB1-D4-1P | MCB1-D4-2P | MCB1-D4-3P | MCB1-D4-4P | |
| 6 | MCB1-D6-1P | MCB1-D6-2P | MCB1-D6-3P | MCB1-D6-4P | |
| 10 | MCB1-D10-1P | MCB1-D10-2P | MCB1-D10-3P | MCB1-D10-4P | |
| 16 | MCB1-D16-1P | MCB1-D16-2P | MCB1-D16-3P | MCB1-D16-4P | |
| 20 | MCB1-D20-1P | MCB1-D20-2P | MCB1-D20-3P | MCB1-D20-4P | |
| 25 | MCB1-D25-1P | MCB1-D25-2P | MCB1-D25-3P | MCB1-D25-4P | |
| 32 | MCB1-D32-1P | MCB1-D32-2P | MCB1-D32-3P | MCB1-D32-4P | |
| 40 | MCB1-D40-1P | MCB1-D40-2P | MCB1-D40-3P | MCB1-D40-4P | |
| 50 | MCB1-D50-1P | MCB1-D50-2P | MCB1-D50-3P | MCB1-D50-4P | |
| 63 | MCB1-D63-1P | MCB1-D63-2P | MCB1-D63-3P | MCB1-D63-4P | 
Product detail pictures:





Related Product Guide:
Motor Nameplate Current vs. NEC Full Load Current Values | National Electrical Code | Lrd12 Overload Relay
Bing’s support for Google AMP just took a big step forward | 220v Contactor Relay
With our loaded encounter and considerate services, we have now been recognized as a trustworthy supplier for lots of worldwide consumers for Short Lead Time for Lc1d475 Magnetic Contactor Schneider - NB1-63 Three Pole din rail circuit breaker – Simply Buy, The product will supply to all over the world, such as: Swansea , Senegal , Melbourne , The working experience in the field has helped us forged a strong relations with customers and partners both in domestic and international market. For years, our products and solutions have been exported to more than 15 countries in the world and have been widely used by customers.
Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
- 
                          
 
                           Factory made hot-sale type Relay Ac110 Dc220 Fo...
 - 
                          
 
                           Factory source Electrical Magnetic Types - EH-...
 - 
                          
 
                           One of Hottest for Tc Contactor - 3TY7460-0A &...
 - 
                          
 
                           Wholesale Price China Gfci Circuit Breaker - M...
 - 
                          
 
                           Hot New Products Solenoid Coil With 24v - comp...
 - 
                          
 
                           Online Exporter Deutz Starter Motor - 3TB41 Wo...
 