New Delivery for Three Phase Circuit Breaker - 3UA overload relay – Simply Buy Detail:
Type | Rated operat ing current(A) |
Rated voltage(V) |
Current Setting range | |
S3UA-50 | 12.5 | 690 | 0.1-0.1,0.16-0.25,0.25-0.4,0.32-0.63,0.63-0.1,0.8-1.25,1-1.6 1.25-2,1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5 |
|
S3UA-52 | 25 | 690 | 0.1-0.1,0.16-0.25,0.25-0.4,0.32-0.63,1.63-1,0.8-1.25,1-1.6 1.25-2,1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5 10-16,12.5-20,16-25 |
|
S3UA-54 | 32 | 690 | 4-6,6.3-10,10-16,12.5-20,16-25,20-32 | |
S3UA-58 | 80 | 690 | 16-25,20-32,25-40,32-50,40-57,50-63,57-70,63-80 | |
S3UA-59 | 63 | 690 | 0.1-0.16,0.16-0.25,0.25-0.4,0.4-0.63,1.63-1,0.8-1.25,1-1.6,1.25-2 1.6-2.5,2-3.2,2.5-4,3.2-5,4-6.3,5-8,6.3-10,8-12.5,10-16,12.5-20 16-25,20-32,25-40,32-45,40-57,50-63 |
|
S3UA-62 | 180 | 690 | 55-80,63,90,80-110,90-120,110-135,120-150,135-160,150-180 | |
S3UA-66 | 400 | 1000 | 80-125,125-200,200-320,250-400 | |
S3UA-68 | 630 | 1000 | 320,-500,400-630 |
Family | OEM Part no. | amp min | amp max | Contactors suitable for |
3UA50 | 3UA50-40-0A | 0.1 | 0.16 | 3TF30, 3TF31, 3TF40, 3TF41, 3TB40, 3TB41 |
3UA50-40-0C | 0.16 | 0.25 | ||
3UA50-40-0E | 0.25 | 0.4 | ||
3UA50-40-0G | 0.4 | 0.63 | ||
3UA50-40-0J | 0.63 | 1 | ||
3UA50-40-0K | 0.8 | 1.25 | ||
3UA50-40-1A | 1 | 1.6 | ||
3UA50-40-1B | 1.25 | 2 | ||
3UA50-40-1C | 1.6 | 2.5 | ||
3UA50-40-1D | 2 | 3.2 | ||
3UA50-40-1E | 2.5 | 4 | ||
3UA50-40-1F | 3.2 | 5 | ||
3UA50-40-1G | 4 | 6.3 | ||
3UA50-40-1H | 5 | 8 | ||
3UA50-40-1J | 6.3 | 10 | ||
3UA50-40-1K | 8 | 12.5 | ||
3UA50-40-2S | 10 | 14.5 | ||
3UA52 | 3UA52-40-0A | 0.1 | 0.16 | 3TF30, 3TF31, 3TF40, 3TF41, 3TB40, 3TB41 |
3UA52-40-0C | 0.16 | 0.25 | ||
3UA52-40-0E | 0.25 | 0.4 | ||
3UA52-40-0G | 0.4 | 0.63 | ||
3UA52-40-0J | 0.63 | 1 | ||
3UA52-40-0K | 0.8 | 1.25 | ||
3UA52-40-1A | 1 | 1.6 | ||
3UA52-40-1B | 1.25 | 2 | ||
3UA52-40-1C | 1.6 | 2.5 | ||
3UA52-40-1D | 2 | 3.2 | ||
3UA52-40-1E | 2.5 | 4 | ||
3UA52-40-1F | 3.2 | 5 | ||
3UA52-40-1G | 4 | 6.3 | ||
3UA52-40-1H | 5 | 8 | ||
3UA52-40-1J | 6.3 | 10 | ||
3UA52-40-1K | 8 | 12.5 | ||
3UA52-40-2A | 10 | 16 | ||
3UA52-40-2B | 12.5 | 20 | ||
3UA52-40-2C | 16 | 25 | ||
3UA54 | 3UA54-40-1G | 4 | 6.3 | 3TF44, 3TB44 |
3UA54-40-1J | 6.3 | 10 | ||
3UA54-40-2A | 10 | 16 | ||
3UA54-40-2B | 12.5 | 20 | ||
3UA54-40-2C | 16 | 25 | ||
3UA54-40-2D | 20 | 32 | ||
3UA54-40-2Q | 25 | 36 | ||
3UA55 | 3UA55-40-0A | 0.1 | 0.16 | 3TF34, 3TF35, 3TF44, 3TF45 |
3UA55-40-0C | 0.16 | 0.25 | ||
3UA55-40-0E | 0.25 | 0.4 | ||
3UA55-40-0G | 0.4 | 0.63 | ||
3UA55-40-0J | 0.63 | 1 | ||
3UA55-40-0K | 0.8 | 1.25 | ||
3UA55-40-1A | 1 | 1.6 | ||
3UA55-40-1B | 1.25 | 2 | ||
3UA55-40-1C | 1.6 | 2.5 | ||
3UA55-40-1D | 2 | 3.2 | ||
3UA55-40-1E | 2.5 | 4 | ||
3UA55-40-1F | 3.2 | 5 | ||
3UA55-40-1G | 4 | 6.3 | ||
3UA55-40-1H | 5 | 8 | ||
3UA55-40-1J | 6.3 | 10 | ||
3UA55-40-1K | 8 | 12.5 | ||
3UA55-40-2A | 10 | 16 | ||
3UA55-40-2B | 12.5 | 20 | ||
3UA55-40-2C | 16 | 25 | ||
3UA55-40-2D | 20 | 32 | ||
3UA55-40-2Q | 25 | 36 | ||
3UA55-40-2R | 32 | 40 | ||
3UA55-40-8M | 36 | 45 | ||
3UA58 | 3UA58-40-1G | 4 | 6.3 | 3TF46, 3TF47, 3TF48, 3TF49 |
3UA58-40-2B | 12.5 | 20 | ||
3UA58-40-2C | 16 | 25 | ||
3UA58-40-2D | 20 | 32 | ||
3UA58-40-2E | 25 | 40 | ||
3UA58-40-2F | 32 | 50 | ||
3UA58-40-2P | 50 | 63 | ||
3UA58-40-2T | 40 | 57 | ||
3UA58-40-2U | 53 | 80 | ||
3UA58-40-2V | 57 | 70 | ||
3UA58-40-8A | 11 | 17 | ||
3UA58-40-8W | 70 | 88 | ||
3UA59 | 3UA59-40-0A | 0.1 | 0.16 | 3TF30- 3TF35, 3TF40-3TF46 |
3UA59-40-0C | 0.16 | 0.25 | ||
3UA59-40-0E | 0.25 | 0.4 | ||
3UA59-40-0G | 0.4 | 0.63 | ||
3UA59-40-0J | 0.63 | 1 | ||
3UA59-40-0K | 0.8 | 1.25 | ||
3UA59-40-1A | 1 | 1.6 | ||
3UA59-40-1B | 1.25 | 2 | ||
3UA59-40-1C | 1.6 | 2.5 | ||
3UA59-40-1D | 2 | 3.2 | ||
3UA59-40-1E | 2.5 | 4 | ||
3UA59-40-1F | 3.2 | 5 | ||
3UA59-40-1G | 4 | 6.3 | ||
3UA59-40-1H | 5 | 8 | ||
3UA59-40-1J | 6.3 | 10 | ||
3UA59-40-1K | 8 | 12.5 | ||
3UA59-40-2A | 10 | 16 | ||
3UA59-40-2B | 12.5 | 20 | ||
3UA59-40-2C | 16 | 25 | ||
3UA59-40-2D | 20 | 32 | ||
3UA59-40-2E | 25 | 40 | ||
3UA59-40-2M | 32 | 45 | ||
3UA59-40-2P | 50 | 63 | ||
3UA59-40-2T | 40 | 57 | ||
3UA60 | 3UA60-40-2H | 55 | 80 | 3TF49, 3TF50, 3TB50 |
3UA60-40-2W | 63 | 90 | ||
3UA60-40-2X | 80 | 110 | ||
3UA60-40-3H | 90 | 120 | ||
3UA60-40-3J | 110 | 135 | ||
3UA60-40-3J | 110 | 135 | ||
3UA61 | 3UA61-40-2H | 55 | 80 | 3TF51 |
3UA61-40-2W | 63 | 90 | ||
3UA61-40-2X | 80 | 110 | ||
3UA61-40-3H | 90 | 120 | ||
3UA61-40-3J | 110 | 135 | ||
3UA61-40-3K | 120 | 150 | ||
3UA62 | 3UA62-40-2H | 55 | 80 | 3TF52, 3TF53, 3TB52 |
3UA62-40-2W | 63 | 90 | ||
3UA62-40-2X | 80 | 110 | ||
3UA62-40-3H | 90 | 120 | ||
3UA62-40-3J | 110 | 135 | ||
3UA62-40-3K | 120 | 150 | ||
3UA62-40-3L | 135 | 160 | ||
3UA62-40-3M | 150 | 180 | ||
3UA66 | 3UA66-40-2K | 80 | 125 | 3TF54, 3TF55, 3TF56, 3TF57 |
3UA66-40-3B | 125 | 200 | ||
3UA66-40-3C | 160 | 250 | ||
3UA66-40-3D | 200 | 320 | ||
3UA66-40-3E | 250 | 400 | ||
3UA68 | 3UA68-40-3F | 320 | 500 | 3TF57, 3TF68 |
3UA68-40-3G | 400 | 630 | 3TF57, 3TF68 |
Product detail pictures:

Related Product Guide:
In Japan, People Get Charged Up About Amping Down | Circuit Breaker Parts
ClipperCreek Looks To The Future With New 64 Amp Residential & Commercial EVSE | Lrd12 Overload Relay
Our business puts emphasis over the administration, the introduction of talented staff, plus the construction of team building, attempting hard to boost the standard and liability consciousness of personnel customers. Our corporation successfully attained IS9001 Certification and European CE Certification of New Delivery for Three Phase Circuit Breaker - 3UA overload relay – Simply Buy, The product will supply to all over the world, such as: Burundi , Lebanon , moldova , we have 8 years experience of production and 5 years experience in trading with the customers all over the world. our clients mainly distributed in the North America, Africa and Eastern Europe. we can supply high quality products with the very competitive price.

The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.

-
OEM Manufacturer Cal16-11a Contactor Auxiliar -...
-
Manufactur standard Ac ContactorMotor Contactor...
-
Newly Arrival Germany Ac Contactor 3tf3411-0xn2...
-
Factory Promotional 220v Coil 16a Ac Magnetic C...
-
8 Year Exporter Ac Contactor Magnetic - 3TY756...
-
Cheapest Price Reversing Contactor 3td4402-0xf0...