Factory wholesale Cjx2 09-95a Ac Contactor - Motor circuit breaker GV2P06 – Simply Buy Detail:
The most commonly used circuit breaker. with a choice of about 100 auxiliaries and accessories. GV2 and TeSys D or K contactors can be easily assembled as a single block with one accessory.
The high GV2 electrical endurance (up to 100 000 manoeuvres) makes it very suitable for direct manual motor control, especially GV2ME (thermal-magnetic c.b., Ith up to 32 A).
Enclosure mounting is well adapted to GV2P, with their possible extended rotary handle and visible trip indication.
Thermal-magnetic: GV2ME, GV2P, GV3P, for protection against short-circuits, overload, phase loss and phase unbalance They are conforming to, depending of the versions, IEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1 and UL 60497-4-1, CSA 22.2 n° 60497-4-1.
0.16-0.25 | GV2P02 | – | – | – | – | – | 0.4 |
0.25-0.4 | GV2P03 | – | – | – | – | – | 0.4 |
0.4-0.63 | GV2P04 | – | – | – | – | 0.37 | 0.4 |
0.63-1.0 | GV2P05 | – | – | 0.37 | 0.37 | 0.55 | 0.4 |
1.0-1.6 | GV2P06 | – | 0.37 | 0.55 | 0.75 | 1.1 | 0.4 |
1.6-2.5 | GV2P07 | 0.37 | 0.75 | 1.1 | 1.1 | 1.5 | 0.4 |
2.5-4.0 | GV2P08 | 0.75 | 1.5 | 1.5 | 2.2 | 3 | 0.4 |
4-6.3 | GV2P10 | 1.1 | 2.2 | 3 | 3.7 | 4 | 0.4 |
6.0-10.0 | GV2P14 | 2.2 | 4 | 4 | 5.5 | 7.5 | 0.4 |
9.0-14.0 | GV2P16 | 3 | 5.5 | 7.5 | 7.5 | 9 | 0.4 |
13.0-18.0 | GV2P20 | 4 | 7.5 | 9 | 9 | 11 | 0.4 |
17.0-23.0 | GV2P21 | 5.5 | 11 | 11 | 11 | 15 | 0.4 |
20.0-25.0 | GV2P22 | 5.5 | 11 | 11 | 15 | 18.5 | 0.4 |
24.0-32.0 | GV2P32 | 7.5 | 15 | 15 | 18.5 | 26 | 0.4 |
Product detail pictures:

Related Product Guide:
How power works in a data center: What you need to know | 220v Contactor Relay
Portable 120V to 240V Converter; or How to Fast Charge at Your In-Law’s House | Circuit Breaker Parts
To regularly increase the management program by virtue from the rule of "sincerely, good religion and high quality are the base of enterprise development", we greatly absorb the essence of linked products internationally, and constantly produce new goods to satisfy the calls for of shoppers for Factory wholesale Cjx2 09-95a Ac Contactor - Motor circuit breaker GV2P06 – Simply Buy, The product will supply to all over the world, such as: Belarus , Irish , Vietnam , "Good quality, Good service " is always our tenet and credo. We take every effort to control the quality, package, labels etc and our QC will check every detail during producing and before shipment. We have been willing to establish long business relationship with all those who seek the high quality products and good service. We've got set up a wide sales network across European countries, North of America, South of America, Middle East, Africa, East Asia countries.Please contact us now, you will find our expert experience and high quality grades will contribute to your business.

The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!

-
Reasonable price 3 Phase Variable Frequency Ac ...
-
Factory Cheap Auxiliary Contacts Of Contactor -...
-
Special Price for Auxiliary Contactor - Circui...
-
China New Product Load Contactor - MS116 Manua...
-
Factory Outlets Phase Reversal Relay - VS1-12K...
-
OEM manufacturer Automatic Motor Starter - 3RT...