The really abundant projects administration experiences and just one to one particular provider model make the substantial importance of organization communication and our easy understanding of your expectations for Heavy Duty Contactor , Iec Contactor Lc1d115 , Main Contactor Eh-260 , You would not have any communication problem with us. We sincerely welcome customers all over the world to contact us for business cooperation.
Factory For Transit Starter Motor - EH-175 – Simply Buy Detail:

EH series is a 3 pole AC contactor while the EK series is a 4 pole contactor. Both are 100% directly replacement ABB EH EK Magnetic Contactors . The EH is rated operational current 80-800 amp under AC-3 duty, with an insulation voltage up to 660~1000V and suitable for a frequency of 50/60 Hz. It can be mounted in a vertical or horizontal position. 

The EH contactor line has a large number of accessories available including: auxiliary contacts, timers, and mechanical interlocking devices. 

EH coils are available in a wide range of operating voltages and are easily changed. 

Model

200-208V

220-240V

440-480V

550-600V

NEMA/
EEMAC

General Purpose Current

EH 80
EH 90
EH 110
EH 145
EH 175
EH 210
EH 260
EH 300
EH 450
EH 550
EH 700
EH 800

25
30
30
40
50
60
75
100
125
150
200
250

30
30
40
50
60
75
100
100
150
200
250
300

60
60
75
100
125
150
200
250
350
400
500
600

75
75
100
125
150
200
250
250
400
500
600
700

4567

110
125
140
170
190
230
300
350
525
600
715
900

 

EH-80 EH80,  direct replacement/aftermarket contactors for ABB EH80,  3-pole, 3-phase, 80A, 600V, 35HP @ 240V, 70HP @ 480V, 70HP @ 600V,  120VAC coil installed, 2NO/2NC aux contacts, AC contactor
EH-90 EH90,  direct replacement/aftermarket contactors for ABB EH90,  3-pole, 3-phase, 96A, 600V, 35HP @ 240V, 70HP @ 480V, 70HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-100 EH100,  direct replacement/aftermarket contactors for ABB EH100,  3-pole, 3-phase, 120A, 600V, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-110 EH110,  direct replacement/aftermarket contactors for ABB EH110,  3-pole, 3-phase, 120A, 600V, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-145 EH145,  direct replacement/aftermarket contactors for ABB EH145,  3-pole, 3-phase, 145A, 600V, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-175 EH175,  direct replacement/aftermarket contactors for ABB EH175,  3-pole, 3-phase, 185A, 600V, 70HP @ 240V, 125HP @ 480V, 165HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-210 EH210,  direct replacement/aftermarket contactors for ABB EH210,  3-pole, 3-phase, 210A, 600V, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-260 EH260,  direct replacement/aftermarket contactors for ABB EH260,  3-pole, 3-phase, 260A, 600V, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-300 EH300,  direct replacement/aftermarket contactors for ABB EH300,  3-pole, 3-phase, 305A, 600V, 100HP @ 240V, 250HP @ 480V, 250HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-370 EH370,  direct replacement/aftermarket contactors for ABB EH370,  3-pole, 3-phase, 400A, 600V, 140HP @ 240V, 300HP @ 480V, 400HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-550 EH550,  direct replacement/aftermarket contactors for ABB EH550,  3-pole, 3-phase, 550A, 600V, 200HP @ 240V, 400HP @ 480V, 500HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-700 EH700,  direct replacement/aftermarket contactors for ABB EH700,  3-pole, 3-phase, 700A, 600V, 300HP @ 240V, 550HP @ 480V, 650HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-800 EH800,  direct replacement/aftermarket contactors for ABB EH800,  3-pole, 3-phase, 750A, 600V, 300HP @ 240V, 600HP @ 480V, 700HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor

Product detail pictures:

Factory For Transit Starter Motor -
 EH-175 – Simply Buy detail pictures


Related Product Guide:
ZTE’s newest Blade phone features dual cameras, a glass back, and face detection | Lrd12 Overload Relay
Power goes out when pc turns on – Components | Lrd12 Overload Relay

With our leading technology at the same time as our spirit of innovation,mutual cooperation, benefits and growth, we're going to build a prosperous future together with your esteemed firm for Factory For Transit Starter Motor - EH-175 – Simply Buy, The product will supply to all over the world, such as: Estonia , Montreal , Turin , We firmly think that we have the full capability to give you contented merchandise. Wish to collect concerns within you and build a new long-term synergy romantic relationship. We all significantly promise:Csame excellent, better selling price; exact selling price, better quality.
  • It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Merry from Colombia - 2016.12.31 14:53
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Jean from Tunisia - 2016.06.25 12:48
    
    WhatsApp Online Chat !