Chinese Professional Home Breaker - A16-30-10 AC Contactor – Simply Buy Detail:
Maximum UL/CSA horsepower ratings
• Includes NEMA sizes 00 – 3
• CE mark
• Compact space saving design
• Standard auxiliary contact configurations:
A9 – A40 1 N.O. or 1 N.C.
A50 – A110 1 N.O. and 1 N.C.
Can be supplied without auxiliaries
• Additional auxiliary contact blocks are available
• D.C. ratings & D.C. control operation available
• Fast, snap-on DIN rail mounting
• Double break contact design
• Snap-on front mounted accessories
| AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
| Model | Amp | KW@480 | HP@480V | NEMA size | ||
| A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
| A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
| A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
| A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
| A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
| A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
| A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
| A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
| A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
| A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
| A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
| A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
| A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
| A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
| A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
| A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
| A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
Product detail pictures:

















Related Product Guide:
Firefox Monitor will let you know if your data has been stolen | 25 Amp Circuit Breaker
25 things to do before Aug. 25 – Edinboro University News Detail | 220v Contactor Relay
We have now a skilled, performance group to offer excellent support for our consumer. We usually follow the tenet of customer-oriented, details-focused for Chinese Professional Home Breaker - A16-30-10 AC Contactor – Simply Buy, The product will supply to all over the world, such as: Moldova , moldova , azerbaijan , We are always creating new technology to streamline the production, and provide goods with competitive prices and high quality! Customer satisfaction is our priority! You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We will offer our best service to satisfy all your needs! Please contact us right away!
This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
-
Factory source Starter Motor For Jeep Grand Che...
-
2017 New Style Overload Thermal Relay - Motor ...
-
Wholesale Automatic Light Timer - 3RT1944-6A &...
-
Factory directly supply Product Market Auto Rel...
-
Best Price on Customised Stainless Steel Balls ...
-
China Factory for Home Use Contactor - ZL300 &...