| AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
| Model | Amp | KW@480 | HP@480V | NEMA size | ||
| A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
| A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
| A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
| A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
| A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
| A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
| A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
| A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
| A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
| A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
| A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
| A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
| A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
| A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
| A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
| A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
| A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
| A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
| A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
Product detail pictures:

















Related Product Guide:
Power goes out when pc turns on – Components | 25 Amp Circuit Breaker
Motor Nameplate Current vs. NEC Full Load Current Values | National Electrical Code | Lrd12 Overload Relay
continue on to further improve, to make sure product top quality in line with market and consumer standard requirements. Our firm has a excellent assurance program have already been established for China Gold Supplier for Short Circuit Breaker - A9-30-10 AC Contactor – Simply Buy, The product will supply to all over the world, such as: Sheffield , Argentina , Philippines , We also provide OEM service that caters to your specific needs and requirements. With a strong team of experienced engineers in hose design and development, we value every opportunity to provide best products for our customers.
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
-
Free sample for Lc1-d170 Ac Contactor - Motor ...
-
Cheapest Factory High Power Current Car Relay -...
-
Discountable price 7.2/12kv High Voltage Ac Con...
-
professional factory for Dc Motor Contactor - ...
-
Factory wholesale Hot Sale Hdpe Coil Pipe Produ...
-
Newly Arrival Tungsten Copper Contactors - Loa...