We bring clear power for the world

Best-Selling For Renault V.i. Starter Motor - EH550 Contactor directly repalcement ASEA EH-550 3P – Simply Buy

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for Mccb Circuit Breaker , C65 Din Rail Circuit Breaker , Auxiliary Contactor , We welcome new and previous buyers from all walks of life to make contact with us for upcoming organization associations and mutual good results!
Best-Selling For Renault V.i. Starter Motor - EH550 Contactor directly repalcement ASEA EH-550 3P – Simply Buy Detail:

EH series is a 3 pole AC contactor while the EK series is a 4 pole contactor. Both are 100% directly replacement ABB EH EK Magnetic Contactors . The EH is rated operational current 80-800 amp under AC-3 duty, with an insulation voltage up to 660~1000V and suitable for a frequency of 50/60 Hz. It can be mounted in a vertical or horizontal position. 

The EH contactor line has a large number of accessories available including: auxiliary contacts, timers, and mechanical interlocking devices. 

EH coils are available in a wide range of operating voltages and are easily changed. 

Model

200-208V

220-240V

440-480V

550-600V

NEMA/
EEMAC

General Purpose Current

EH 80
EH 90
EH 110
EH 145
EH 175
EH 210
EH 260
EH 300
EH 450
EH 550
EH 700
EH 800

25
30
30
40
50
60
75
100
125
150
200
250

30
30
40
50
60
75
100
100
150
200
250
300

60
60
75
100
125
150
200
250
350
400
500
600

75
75
100
125
150
200
250
250
400
500
600
700

4567

110
125
140
170
190
230
300
350
525
600
715
900

 

EH-80 EH80,  direct replacement/aftermarket contactors for ABB EH80,  3-pole, 3-phase, 80A, 600V, 35HP @ 240V, 70HP @ 480V, 70HP @ 600V,  120VAC coil installed, 2NO/2NC aux contacts, AC contactor
EH-90 EH90,  direct replacement/aftermarket contactors for ABB EH90,  3-pole, 3-phase, 96A, 600V, 35HP @ 240V, 70HP @ 480V, 70HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-100 EH100,  direct replacement/aftermarket contactors for ABB EH100,  3-pole, 3-phase, 120A, 600V, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-110 EH110,  direct replacement/aftermarket contactors for ABB EH110,  3-pole, 3-phase, 120A, 600V, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-145 EH145,  direct replacement/aftermarket contactors for ABB EH145,  3-pole, 3-phase, 145A, 600V, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-175 EH175,  direct replacement/aftermarket contactors for ABB EH175,  3-pole, 3-phase, 185A, 600V, 70HP @ 240V, 125HP @ 480V, 165HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-210 EH210,  direct replacement/aftermarket contactors for ABB EH210,  3-pole, 3-phase, 210A, 600V, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-260 EH260,  direct replacement/aftermarket contactors for ABB EH260,  3-pole, 3-phase, 260A, 600V, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-300 EH300,  direct replacement/aftermarket contactors for ABB EH300,  3-pole, 3-phase, 305A, 600V, 100HP @ 240V, 250HP @ 480V, 250HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-370 EH370,  direct replacement/aftermarket contactors for ABB EH370,  3-pole, 3-phase, 400A, 600V, 140HP @ 240V, 300HP @ 480V, 400HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-550 EH550,  direct replacement/aftermarket contactors for ABB EH550,  3-pole, 3-phase, 550A, 600V, 200HP @ 240V, 400HP @ 480V, 500HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-700 EH700,  direct replacement/aftermarket contactors for ABB EH700,  3-pole, 3-phase, 700A, 600V, 300HP @ 240V, 550HP @ 480V, 650HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor
EH-800 EH800,  direct replacement/aftermarket contactors for ABB EH800,  3-pole, 3-phase, 750A, 600V, 300HP @ 240V, 600HP @ 480V, 700HP @ 600V,  120VAC coil installed, 2NO/2NC aux contact, AC contactor

Product detail pictures:

Best-Selling For Renault V.i. Starter Motor -
 EH550 Contactor directly repalcement ASEA EH-550 3P – Simply Buy detail pictures


Related Product Guide:
Things Your Electrician Wishes You Knew | 19mm Momentary Push Button
Nvidia unveils Turing architecture and GPUs with dedicated ray-tracing hardware | 220v Contactor Relay

We are also focusing on improving the stuff management and QC system so that we could keep great advantage in the fiercely-competitive business for Best-Selling For Renault V.i. Starter Motor - EH550 Contactor directly repalcement ASEA EH-550 3P – Simply Buy, The product will supply to all over the world, such as: Porto , Albania , Comoros , Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Eileen from Angola - 2016.04.18 16:45
    The company's products very well, we have purchased and cooperated many times, fair price and assured quality, in short, this is a trustworthy company!
    5 Stars By Gladys from Lisbon - 2015.10.01 14:14
    
    WhatsApp Online Chat !