Best Price on Automatic Star Delta Starter - Rapid Delivery for 12v 24v 36v 48v 60v 72v 50a Electric Forklift Dc Contactor Electric Grab Winch Evq/evh50a – Simply Buy Detail:
High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for Rapid Delivery for 12v 24v 36v 48v 60v 72v 50a Electric Forklift Dc Contactor Electric Grab Winch Evq/evh50a, Welcome buddies from all over the earth come to visit, tutorial and negotiate.
High quality Initial,and Buyer Supreme is our guideline to offer the ideal assistance to our shoppers.At present, we are striving our best to become amongst the ideal exporters inside our industry to satisfy shoppers more want for Aeg Contactor, Contactor 110V dc, No Nc Auxiliary Contactor, Our solutions are widely recognized and trusted by users and can meet continuously changing of economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
Nofuel NC1D Series Magnetic Contactors have been engineered for superior performance under Hazardous tropical conditions, conforming to IS/IEC 60947-4-1; IS/IEC 60947-1. It’s robust construction with heavy duty silver alloy contacts, encapsulated coil in higher range to withstand wide voltage fluctuations delivers long life. Contactor have high insulation strength, with high making and breaking capacity. The Contactor Base with Télémécanique motor control technology since 1924
Advantage
- Extremely easy maintenance
- Easy coil replacement
- Low down time for Contactor maintenance
- Contactor is ideally suitable for standalone applications such as welding, compressor, motor control & machine tools etc
Certificate : UL CSA RU CCC CE RoHS
- 9A ~ 95A (AC3 rating)
- 3 & 4 Pole Contactor
- 4 Frame sizes
- 115A ~ 800A (AC3 rating)
- 3 & 4 Pole Contactor
- 8 Frame sizes
Industrial Applications
- Motor Controls
- Pumps
- Machine Tools
- Printing & Packaging Machines
- Compressors
- Power Supply Solutions
- HVAC
- Cranes
- Elevators & Escalators
- Windmills
- Solar Systems


Nofuel Contactor Series– 3 Pole
Conforming: IS 13947-4-1 / IEC 60947-4-1
Technical Parameters-Contactor: 9A~95A
|
AC Types3 Pole DC |
NC1D-09 |
NC1D-12 |
NC1D-18 |
NC1D-25 |
|
NP1D-09 |
NP1D-12 |
NP1D-18 |
NP1D-25 |
|
|
Maximum Rated Current for AC3 Duty |
9A |
12A |
18A |
25A |
|
Rated Operational Voltage: Ue |
690 |
|||
|
Thermal Current: Ith |
25A |
32A |
40A |
|
|
Power Rating for Motor Control for AC3 Duty Ø <=55°C,415V
Conforming to UL, CSA230V 460/480V 575/600V |
KW / HP 4 / 5.5 |
KW / HP 5.5 / 7.5 |
KW / HP 9 / 12.5 |
KW / HP 11 / 15 |
|
2 |
3 |
5 |
7.5 |
|
|
5 |
7.5 |
10 |
15 |
|
|
7.5 |
10 |
15 |
20 |
|
|
Mounting Position |
±30 |
|||
|
Ambient Air Temperature (Operational) |
- 5 to + 55°C |
|||
|
Maximum Operating Rate Operations / Hrs.AC / DC |
3600 |
|||
|
Mechanical Life50-60 Hz |
20 |
|||
|
Thermal / Electronic Overload Relay |
0.10~13.0 |
13.0~37.0 |
||
|
Auxiliary Contact BlockFront Mounted: Side Mounted: |
1 NO, 1NC, 2NO, 1 NO+1NC, 2NC, 4NO, 3NO+1NC, 2NO+2NC, 1NO+3NC, 4NC |
|||
|
1NO+1NC, 2NC |
||||
|
Pneumatic TimerFront Mounted: Star Delta Timer: |
On Delay 1NO+1NC (0.1~180 Sec) OFF Delay 1NO+1NC (0.1~180 Sec) |
|||
|
1 NO+1NC (0.1~30 Sec) |
||||
|
Mechanical InterlockHorizontally Mounted: |
AC: NC1D09 - NC1D95DC: NP1D09 - NP1D95 |
|||
|
Surge Suppressor |
Varistor AC/DC:24~48V,110~240V RC Circuit AC:24~48V,110~240V, 380~440V |
|||
AC Coil Voltage for
3 Pole Contactors 9A~95A & Control Relays
| Coils Code |
Voltage |
| TX1-D |
24 48 110 220 240 380 415 |
| 50/60 Hz |
B7 E7 F7 M7 U7 Q7 N7 |
|
NC1D-32 |
NC1D-40 |
NC1D-50 |
NC1D-65 |
NC1D-80 |
NC1D-95 |
|
BLP1D-32 |
NP1D-40 |
NP1D-50 |
NP1D-65 |
NP1D-80 |
NP1D-95 |
|
32A |
40A |
50A |
65A |
80A |
95A |
690
| 50A | 60A |
80A |
125A |
||
| KW / HP15 / 20 |
KW / HP 22 / 30 |
KW / HP 25 / 35 |
KW / HP 37 / 50 |
KW / HP 45 / 60 |
KW / HP 45 / 60 |
| 10 | 10 |
15 |
20 |
25 |
25 |
| 20 | 30 |
40 |
50 |
60 |
60 |
| 25 | 30 |
40 |
50 |
60 |
60 |
±30
- 5 to + 55°C 3600
50-60 Hz
| 13.0~37.0 |
40.0~63.0 |
63.0~93.0 |
DC Coil Voltage for
3 Pole Contactors 9A~95A & Control Relays
| Coils Code |
Voltage |
| TX4-D | 12 24 48 72 110 125 220 250 440 |
| Nominal Coil | JD BD ED SD FD GD MD UD RD |
Outline and Mounting Dimensions in mm
NC1D50 – NC1D65
NC1D1801
NC1D80 – BLC1D95
Product detail pictures:

















Related Product Guide:
Motor Nameplate Current vs. NEC Full Load Current Values | National Electrical Code | 220v Contactor Relay
Microsoft announces Xbox One keyboard and mouse support with Razer partnership | 25 Amp Circuit Breaker
We'll make every effort and hard work to be superb and excellent, and speed up our steps for standing inside the rank of intercontinental top-grade and high-tech enterprises for Best Price on Automatic Star Delta Starter - Rapid Delivery for 12v 24v 36v 48v 60v 72v 50a Electric Forklift Dc Contactor Electric Grab Winch Evq/evh50a – Simply Buy, The product will supply to all over the world, such as: Juventus , Czech republic , Southampton , What is good price? We provide customers with factory price. In the premise of good quality, efficiency must be paid attention to and maintain appropriate low and healthy profits. What is a fast delivery? We make the delivery according to customers' requirements. Although delivery time depends on the order quantity and the complexity of it, we still try to supply products in time. Sincerely hope we could have long term business relationship.
The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!