2017 wholesale price Assembly Line For Trucks - A185-30-11 A line Contactor – Simply Buy Detail:
Maximum UL/CSA horsepower ratings
• Includes NEMA sizes 00 – 3
• CE mark
• Compact space saving design
• Standard auxiliary contact configurations:
A9 – A40 1 N.O. or 1 N.C.
A50 – A110 1 N.O. and 1 N.C.
Can be supplied without auxiliaries
• Additional auxiliary contact blocks are available
• D.C. ratings & D.C. control operation available
• Fast, snap-on DIN rail mounting
• Double break contact design
• Snap-on front mounted accessories
AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
Model | Amp | KW@480 | HP@480V | NEMA size | ||
A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
Product detail pictures:
Related Product Guide:
Toyota Corolla 2.0 hybrid hatchback 2019 review | 220v Contactor Relay
Does Tesla Make The Best Value EVSE For Non-Tesla Owners? | Lrd12 Overload Relay
Our rewards are reduce selling prices,dynamic revenue team,specialized QC,sturdy factories,superior quality services for 2017 wholesale price Assembly Line For Trucks - A185-30-11 A line Contactor – Simply Buy, The product will supply to all over the world, such as: Macedonia , Mexico , Austria , Abiding by our motto of "Hold well the quality and services, Customers Satisfaction", So we give our clients with high quality products and solutions and excellent service. Be sure to feel free to contact us for further information.
By Jacqueline from Japan - 2015.06.18 19:26
The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
By Poppy from Mumbai - 2016.08.16 13:39