Features:
| 3RT1015 | Power contactor, AC-3 7 A, 3 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1015 |
| 3RT1016 | Power contactor, AC-3 9 A, 4 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1016 |
| 3RT1017 | Power contactor, AC-3 12 A, 5.5 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1017 |
| 3RT1023 | Power contactor, AC-3 9 A, 4 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1023 |
| 3RT1024 | Power contactor, AC-3 12 A, 5.5 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1024 |
| 3RT1025 | Power contactor, AC-3 17 A, 7.5 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1025 |
| 3RT1026 | Power contactor, AC-3 25 A, 11 kW / 400 V 3-pole Size S0, Screw terminal direct replacement Siemens Sirius 3RT1026 |
| 3RT1034 | Power contactor, AC-3 32 A, 15 kW / 400 V 3-pole Size S2, Screw terminal direct replacement Siemens Sirius 3RT1034 |
| 3RT1035 | Power contactor, AC-3 40 A, 18.5 kW / 400 V 3-pole Size S2, Screw terminal direct replacement Siemens Sirius 3RT1035 |
| 3RT1036 | Power contactor, AC-3 50 A, 22 kW / 400 V 3-pole Size S2, Screw terminal direct replacement Siemens Sirius 3RT1036 |
| 3RT1044 | Power contactor, AC-3 65 A, 30 kW / 400 V 3-pole Size S3, Screw terminal direct replacement Siemens Sirius 3RT1044 |
| 3RT1045 | Power contactor, AC-3 80 A, 37 kW / 400 V 3-pole Size S3, Screw terminal direct replacement Siemens Sirius 3RT1045 |
| 3RT1046 | Power contactor, AC-3 95 A, 45 kW / 400 V 3-pole Size S3, Screw terminal direct replacement Siemens Sirius 3RT1046 |
| AC Control supply Model No. |
Standard Part Number |
Rade Amp AC-3 400 V |
AC-3 Rated operational power |
3-phase motor rating |
Frame Size | Weight in kg |
| A 400V | KW@400V | HP@480V | ||||
| 3RT1015 | 3RT1015 | 7 | 3 | 3 | S00 | 0.4 |
| 3RT1016 | 3RT1016 | 9 | 4 | 5 | S00 | 0.4 |
| 3RT1017 | 3RT1017 | 12 | 5.5 | 7.5 | S00 | 0.4 |
| 3RT1023 | 3RT1023 | 9 | 4 | 5 | S0 | 0.6 |
| 3RT1024 | 3RT1024 | 12 | 5.5 | 7.5 | S0 | 0.8 |
| 3RT1025 | 3RT1025 | 17 | 7.5 | 10 | S0 | 0.8 |
| 3RT1026 | 3RT1026 | 25 | 11 | 15 | S0 | 1.2 |
| 3RT1034 | 3RT1034 | 32 | 15 | 25 | S2 | 1.2 |
| 3RT1035 | 3RT1035 | 40 | 18.5 | 30 | S2 | 1.2 |
| 3RT1036 | 3RT1036 | 50 | 22 | 40 | S2 | 2.2 |
| 3RT1044 | 3RT1044 | 65 | 30 | 50 | S3 | 2.2 |
| 3RT1045 | 3RT1045 | 80 | 37 | 60 | S3 | 2.2 |
| 3RT1046 | 3RT1046 | 95 | 45 | 75 | S3 | 3.5 |
|
Nofuel Part # |
Coil Voltage |
HP Ratings @230V |
HP Ratings @460V |
Amp |
|
3RT1015 |
120 |
2 |
3 |
7 |
|
3RT1015-1AB01 |
24 |
2 |
3 |
7 |
|
3RT1015-1AK61 |
120 |
2 |
3 |
7 |
|
3RT1015-1AP61 |
240 |
2 |
3 |
7 |
|
3RT1015-1AV61 |
480 |
2 |
3 |
7 |
|
3RT1016 |
120 |
3 |
5 |
9 |
|
3RT1016-1AB01 |
24 |
3 |
5 |
9 |
|
3RT1016-1AK61 |
120 |
3 |
5 |
9 |
|
3RT1016-1AP61 |
240 |
3 |
5 |
9 |
|
3RT1016-1AV61 |
480 |
3 |
5 |
9 |
|
3RT1017 |
120 |
3 |
7.5 |
12 |
|
3RT1017-1AB01 |
24 |
3 |
7.5 |
12 |
|
3RT1017-1AK61 |
120 |
3 |
7.5 |
12 |
|
3RT1017-1AP61 |
240 |
3 |
7.5 |
12 |
|
3RT1017-1AV61 |
480 |
3 |
7.5 |
12 |
|
3RT1023 |
120 |
3 |
5 |
9 |
|
3RT1023-1AB01 |
24 |
3 |
5 |
9 |
|
3RT1023-1AK61 |
120 |
3 |
5 |
9 |
|
3RT1023-1AP61 |
240 |
3 |
5 |
9 |
|
3RT1023-1AV61 |
480 |
3 |
5 |
9 |
|
3RT1024 |
120 |
3 |
7.5 |
12 |
|
3RT1024-1AB01 |
24 |
3 |
7.5 |
12 |
|
3RT1024-1AK61 |
120 |
3 |
7.5 |
12 |
|
3RT1024-1AP61 |
240 |
3 |
7.5 |
12 |
|
3RT1024-1AV61 |
480 |
3 |
7.5 |
12 |
|
3RT1025 |
120 |
5 |
10 |
17 |
|
3RT1025-1AB01 |
24 |
5 |
10 |
17 |
|
3RT1025-1AK61 |
120 |
5 |
10 |
17 |
|
3RT1025-1AP61 |
240 |
5 |
10 |
17 |
|
3RT1025-1AV61 |
480 |
5 |
10 |
17 |
|
3RT1026 |
120 |
7.5 |
15 |
25 |
|
3RT1026-1AB01 |
24 |
7.5 |
15 |
25 |
|
3RT1026-1AK61 |
120 |
7.5 |
15 |
25 |
|
3RT1026-1AP61 |
240 |
7.5 |
15 |
25 |
|
3RT1026-1AV61 |
480 |
7.5 |
15 |
25 |
|
3RT1034 |
120 |
10 |
25 |
32 |
|
3RT1034-1AB01 |
24 |
10 |
25 |
32 |
|
3RT1034-1AK61 |
120 |
10 |
25 |
32 |
|
3RT1034-1AP61 |
240 |
10 |
25 |
32 |
|
3RT1034-1AV61 |
480 |
10 |
25 |
32 |
|
3RT1035 |
120 |
15 |
30 |
40 |
|
3RT1035-1AB01 |
24 |
15 |
30 |
40 |
|
3RT1035-1AK61 |
120 |
15 |
30 |
40 |
|
3RT1035-1AP61 |
240 |
15 |
30 |
40 |
|
3RT1035-1AV61 |
480 |
15 |
30 |
40 |
|
3RT1036 |
120 |
15 |
40 |
50 |
|
3RT1036-1AB01 |
24 |
15 |
40 |
50 |
|
3RT1036-1AK61 |
120 |
15 |
40 |
50 |
|
3RT1036-1AP61 |
240 |
15 |
40 |
50 |
|
3RT1036-1AV61 |
480 |
15 |
40 |
50 |
|
3RT1044 |
120 |
25 |
50 |
65 |
|
3RT1044-1AB01 |
24 |
25 |
50 |
65 |
|
3RT1044-1AK61 |
120 |
25 |
50 |
65 |
|
3RT1044-1AP61 |
240 |
25 |
50 |
65 |
|
3RT1044-1AV61 |
480 |
25 |
50 |
65 |
|
3RT1045 |
120 |
30 |
60 |
65 |
|
3RT1045-1AB01 |
24 |
30 |
60 |
65 |
|
3RT1045-1AK61 |
120 |
30 |
60 |
65 |
|
3RT1045-1AP61 |
240 |
30 |
60 |
65 |
|
3RT1045-1AV61 |
480 |
30 |
60 |
65 |
|
3RT1046 |
120 |
30 |
75 |
95 |
|
3RT1046-1AB01 |
24 |
30 |
75 |
95 |
|
3RT1046-1AK61 |
120 |
30 |
75 |
95 |
|
3RT1046-1AP61 |
240 |
30 |
75 |
95 |
|
3RT1046-1AV61 |
480 |
30 |
75 |
95 |
Product detail pictures:



















Related Product Guide:
What to Consider When Buying and Installing a Home Electric Vehicle Charging Station | 25 Amp Circuit Breaker
Can Google AMP make the web faster without taking over the web? | Lrd12 Overload Relay
With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for Original Factory 4 Pole Normally Open Contactor - Sirius 3RT Contactor – Simply Buy, The product will supply to all over the world, such as: Greece , Lebanon , Nigeria , we've got all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
-
Popular Design for Cummins Motor Starter - Mot...
-
OEM Manufacturer Cal16-11a Contactor Auxiliar -...
-
OEM Supply 24v Starter 18393 For Truck - Defin...
-
factory Outlets for Opel Astra Corsa Chevy Vaux...
-
OEM Manufacturer Polyester Copper Wire For Seal...
-
Factory directly supply Intelligent Chip Combin...