uri |
Rated nagtatrabaho kasalukuyang A (380V) | 220V |
AC-3 na paggamit ng grupo ng control kapangyarihan (KW) 380V ~ 415V 440 ~ 500V |
660V | Makipag-ugnay sa data (1) | |||
LC1-K06 |
6 |
1.5 |
2.2 |
3 |
3 |
3P + WALANG 3P + NC | ||
LC1-K09 |
9 |
2.2 |
4 |
4 |
4 |
3P + WALANG 3P + NC | ||
LC1-K12 |
12 |
3 |
3 |
5 |
5 |
3P + WALANG 3P + NC |
Mismong LC1-K06 LC1-K09 LC1-K12 | |||||
Gamitin group sa ilalim AC-3 |
6 |
9 |
12 |
||
Rated nagtatrabaho kasalukuyang (le) Isang |
5 |
7.5 |
10 |
||
Maginoo thermal kasalukuyang (lth) Isang |
16 |
20 |
20 |
||
Rate nagtatrabaho boltahe (Ue) V |
380 660 |
||||
Rated insullation boltahe (Ui) V |
690 |
||||
AC-3 (6le le) | Electrical buhay (oras) |
0.5 × 106 |
|||
Operation frequency h-1 |
1200 |
||||
AC-3 (6le le) | Electrical buhay (oras) |
10 × 104 |
|||
Operation frequency h-1 |
300 |
||||
Mecnical buhay Pandiwang pantulong contact | Maginoo thermal kasalukuyang |
3 × 106 6A |
|||
Electrical buhay (oras) | AC-15 (360VA) |
0.5 × 106 |
|||
DC-13 (33W) | |||||
pagtutukoy Coil | Rated control boltahe (sa Amin) | AC: 12, 24, 45, 110, 220, 380 | |||
DC: 12, 24, 45, 110, 220 | |||||
Pick-up boltahe | AC: 0.85 ~ 1.1Us DC: 0.85 ~ 1.1Us | ||||
Resleasing boltahe | AC: 0.2 ~ 0.75Us DC: 0.2 ~ 0.75Us | ||||
Likawin kapangyarihan VA | Pulutin |
40 |
|||
Fotain |
4 |
||||
paggamit |
1.2W |
||||
Oras ng pagkuha |
6 ~ 18ms |
||||
Ilalabas time Power kadahilanan |
5 ~ 23ms Gumagawa 0.8 Breaking 0.3 |
AC operating coils
Maximum Horsepower Ratings | maximum Kasalukuyang | Uri ng koneksyon | Auxiliary Contact s | catalog Number |
|||||||
1 Ø | 3 Ø | Pasaklaw AC3 amperes |
resistive AC1 amperes |
||||||||
115 V hp | 230 V hp | 200 V hp | 230 V hp | 460 V hp | 575 V hp | HINDI | NC | ||||
0.5 | 1.5 | 1.5 | 1.5 | 3 | 3 | 6 | 15 | Maluwag ang tornilyo-salansan | 1- | -1 | LC1K 0610 LC1K0601 |
0.5 | 1.5 | 2 | 3 | 5 | 5 | 9 | 20 | Maluwag ang tornilyo-salansan | 1- | -1 | LC1K0910 LC1K0901 |
0.5 | 1.5 | 3 | 3 | 7.5 | 10 | 12 | 20 | Maluwag ang tornilyo-salansan | 1- | -1 | LC1K1210 LC1K1201 |
Likawin boltahe code para sa AC contactors
Volts AC 50/60 Hz | 12 |
24 |
42 | 48 | 110 | 120 | 127 | 200 / 208 |
220 / 230 |
230 | 230 / 240 |
277 | 380 / 400 |
400 / 415 |
440 | 480 |
kodigo | J7 |
B7 |
D7 | E7 | F7 | G7 | FC7 | L7 | M7 | P7 | U7 | UE7 | Q7 | N7 | R7 | T7 |
DC operating coils
0.5 | 1.5 | 1.5 | 1.5 | 3 | 3 | 6 | 15 | Maluwag ang tornilyo-salansan | 1- | -1 | LP1K0610 ab LP1K0601 ab |
0.5 | 1.5 | 2 | 3 | 5 | 5 | 9 | 20 | Maluwag ang tornilyo-salansan | 1- | -1 | LP1K0910 ab LP1K0901 ab |
0.5 | 1.5 | 3 | 3 | 7.5 | 10 | 12 | 20 | Maluwag ang tornilyo-salansan | 1- | -1 | LP1K1210 ab LP1K1201 ab |
Overload relays para sa 3-Pole contactors may maluwag ang tornilyo-salansan terminals
Class 10, Relay setting range-A | Bilang catalog | |
0.1-0.16 | LR2K0301 | LR2K Sobra relays:
|
0.16-0.23 | LR2K0302 | |
0.23-0.36 | LR2K0303 | |
0.36-0.54 | LR2K0304 | |
0.54-0.8 | LR2K0305 | |
0.8-1.2 | LR2K0306 | |
1.2-1.8 | LR2K0307 | |
1.8-2.6 | LR2K0308 | |
2.6-3.7 | LR2K0310 | |
3.8-5.5 | LR2K0312 | |
5.5-8 | LR2K0314 | |
8-11.5 | LR2K0316 | |
10 hanggang 14 | LR2K0321 |